[ ] MediLauncher for QEEG software [WinEEG-Overlay]
MediLauncher for QEEG – Guided and Automated Workflow for MITSAR WinEEG
SHORT DESCRIPTION
QEEG with WinEEG – simpler, safer and more efficient.
MediLauncher guides users step by step through the complete QEEG workflow, applies the intended settings in WinEEG, synchronises client records and automatically initiates the selected WinEEG analyses. Finally, the generated results are consolidated into a single Word document.
This turns numerous individual operating steps into a clear and reproducible process – from preparation and recording through to the completed report.
DETAILED PRODUCT DESCRIPTION
MediLauncher for QEEG is the workflow and automation software developed by MediTECH for MITSAR WinEEG. It reduces operating complexity, guides users through the required steps and supports a consistent and traceable procedure.
WinEEG provides extensive options for EEG recording and QEEG analysis. However, selecting the correct settings, creating and assigning client records, and running several analyses may require numerous individual operating steps. This is exactly where MediLauncher comes in.
Its clearly structured user interface allows users to select the required workflow:
• Recording
• Analysis of an existing recording
• Recording followed by analysis
MediLauncher initially checks system readiness and then guides the user step by step through the selected workflow. Instructions covering client preparation, electrode application and impedance assessment support a standardised procedure. The required WinEEG settings and operating steps are prepared or performed automatically.
Client information is managed centrally within MediLauncher and synchronised with the corresponding WinEEG records. Existing clients can be assigned reliably, while new clients can be created in a structured manner and used throughout the subsequent workflow.
Once the EEG recording has been completed, MediLauncher initiates the configured WinEEG analysis options. The generated results are verified, collected and consolidated into a single Word document. Instead of handling several separately generated output files, users receive one coherent basis for documentation, professional review and report preparation.
YOUR BENEFITS
• Guided workflow from client registration to analysis
• Considerably simplified operation of WinEEG
• Automatic preparation of the intended WinEEG settings
• Consistent and reproducible operating procedures
• Reduced risk of operating errors and omitted workflow steps
• Integrated client database with WinEEG synchronisation
• Support for client preparation, electrode application and impedance control
• Automated initiation of the selected WinEEG analyses
• Consolidation of the generated results into a single Word document
• Status and plausibility checks throughout the workflow
• Time savings in recording, analysis and documentation
• Particularly suitable for organisations with several users or standardised examination procedures
KEY FUNCTIONS
System readiness check
Before the workflow starts, MediLauncher checks the relevant system components and provides a clear overview of their current status. Any detected issues become visible before recording or analysis begins.
Guided client management
The integrated client database supports the reliable creation, selection and assignment of client records. MediLauncher synchronises relevant data with WinEEG and helps maintain consistent records.
Guided preparation and impedance control
Illustrated instructions and clearly defined target values assist users with client preparation, correct EEG cap placement, electrode preparation and impedance assessment.
Automated WinEEG control
MediLauncher opens the required WinEEG functions, applies the settings intended for the selected workflow and guides the user through the necessary steps. This standardises and simplifies recurring procedures.
Recording and analysis within one workflow
In addition to separate recording and analysis workflows, MediLauncher provides an integrated procedure combining recording and subsequent analysis.
Consolidated report output
The configured WinEEG analyses are initiated automatically. The generated results are subsequently consolidated into one Word document and made available for further use.
FIELDS OF APPLICATION
MediLauncher is particularly suitable for:
• neurological, psychiatric and psychotherapeutic facilities
• QEEG and neurofeedback practices
• hospitals and outpatient departments
• research and educational institutions
• organisations with several WinEEG users
• standardised EEG and QEEG procedures
REQUIREMENTS AND SCOPE
MediLauncher extends and controls a compatible MITSAR WinEEG workstation. A suitable and properly licensed WinEEG installation and the EEG hardware required for the intended application are prerequisites. They are not included with this product unless expressly specified in the relevant quotation.
MediLauncher does not replace WinEEG or the professional qualifications of the user. It structures and automates the technical workflow. Review, assessment and interpretation of EEG and QEEG results remain the responsibility of appropriately qualified professionals.
Please ask MediTECH to confirm compatibility with your existing WinEEG version and system configuration before ordering.